Print This Page

Vibration and Position Monitor Models

Vibration and Position Monitors
Model # Description Operating Voltage Filter Setpoint Relay Contacts Sensor
V/P-SCF Displacement 24 VDC Yes One Form C A1 Pickup (Internal)
V/P-SCF Displacement 115 VAC Yes One Form C A1 Pickup (Internal)
V/P-SCV Velocity 24 VDC Yes One Form C A1 Pickup (Internal)
V/P-SCV Velocity 115 VAC Yes One Form C A1 Pickup (Internal)
V/P-SCD Displacement 24 VDC Available Dual Form A or B A1 Pickup
V/P-SCD Displacement 115 VAC Available Dual Form A or B A1 Pickup
V/P-LR2D Displacement 24 VDC No  Dual Form A, B, or C LG Probe
V/P-LR4C Displacement 115 VAC No  Dual Form C LG Probe
G/P-LR3 Axial Position 24 VDC No  Dual Form C LG Probe
G/P-LR3C Axial Position 115 VAC No  Dual Form C LG Probe
V/P-SCOV2 Velocity 24 VDC Yes Dual Form A, B, or C Velocity Transducer
V/P-SCOVC Velocity 115 VAC Yes Dual Form A, B, or C Velocity Transducer

 

Operating Range: Vibration/Displacement – 0-3, 0-5, 0-10, 0-15 mils peak-to-peak/Velocity – 0-0.5, 0-1 inch/sec. Position/ 0-10-0, 0-25-0, 40-0-40 mils
Analog Output: 0-1 VDC, 0-5 VDC, 1-5 VDC, 0-10 VDC, 4-20mA analog
Time Delay: The alarm and trip time delay are fixed: 0.5, 1, 2, 3, 5, or 10 seconds
Relay Rating: Relays are rated 5A at 28 VDC or 115 VAC (resistive)
Contact Configuration: Form A = normally open, Form B = normally closed, Form C = available in both normally open or closed
HSP: Automatically increases setpoint levels by a factor 2-5 times during start-up. Prevents premature setpoint action