| XT101 ? VIBRATION (input from
Indikon Proximity Probe or A3J
Seismic Pickup.) XT121 ? VIBRATION (input from accelerometers) XT131 ? VIBRATION (input from velocity transducer) XT103 ? POSITION (input from Indikon Proximity Probe) CONNECT TO: |
FEATURES ? ?40?C to +85?C 15 to 36 volts 25 +/- 4 mA to 180 mA |
|
||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
| Controls loop current in proportion to vibration sensed by proximity probe or seismic pickup. | SPECIFICATIONS Standard Vibration Ranges See table below Loop Current - 4-20mA DC Not ok <3.3mA or >21mA Frequency Response 600-240,000 CPM (-5% pts) 180-300,000 CPM (-3db pts) |
Diagnostic and Auxiliary Signal Output: 50,100 or 200 mv/mil based on probe used. Adjustable Zero Sensor: Indikon Proximity Probe or Displacement Pickup Target Material AISI 4140 or 4340 Steel. Consult Factory. Cable: Specify in increments of 5' up to 50' |
||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
| Controls loop current in proportion to vibration sensed by accelerometer | SPECIFICATIONS Standard Vibration Ranges See table below. Loop Current: - 4-20 mA DC Not ok <3.3mA OR >21mA Frequency Response: Depends on range, filter and specified filter (9 poles) |
Diagnostic and Auxiliary Signal Output: 100 or 200 mV/ inch/sec based on input or range. Adjustable Zero Sensor: Accelerometer Model A-90 or accelerometer of any sensitivity. (charge-coupled) Cable: Consult Factory. |
||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
| Controls loop current in proportion to vibration sensed by velocity transducer | SPECIFICATION Standard Vibration Ranges See table below Loop Current - 4-20 mA DC Not ok <3.3mA or >21mA Frequency Response: Depends on transducer, range or specified filter (up to 10 poles) |
Diagnostic and Auxiliary Signal Output: 200 mV/ mil or 100, 200mV/ inch/sec Adjustable Zero Sensor: Velocity Transducer of any sensitivity above 100mV/ inch/sec Self-Generating not requiring power. Cable: Consult Factory. |
||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
| Controls loop current in proportion to proximity probe gap. | SPECIFICATION Standard Vibration Ranges Depends on probe used. Loop Current - 4-20 mA DC Not ok <3.3mA or >21mA Independent Span Control: (about +/- 10%) |
Diagnostic and Auxiliary Signal Output: 20, 50, 100 or 200 mv/mil based on probe and/or range. Adjustable Zero Sensor: Indikon Proximity Probe specified. Target Material Specify. Standard is AISI 4140 or 4340 Steel. Cable: Specify in increments of 5' up to 50' |
||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||