Torque And 'Real-Time' Alignment Specifications

Torque Meter Accuracy: 1.0% of Full Scale (FS) rating
Real-Time Alignment Accuracy: Customer Specified
 
Torque Meter Useful Range: 0 Torque to Full Scale
Real-Time Alignment Range: Customer Specified
 
Torque Meter Calibration:

All units are calibrated at the full scale specified by customer

Torque Meter Calibration Accuracy:

0.25% of Full Scale

Standard Date: 5 points Up and Down (0%, 25%, 50%, 75%, FS) for Linearity and Hysteresis
 
Torque Meter and Real-Time Alignment Readout Instrument:

LCD Touch screen

The following outputs are available from the readout instrumentation:
Torque Meter Output Speed/Torque/Horsepower, 4-20mA or 0-10 VDC, Analog Output for Connection to DCS
Real-Time Alignment Output 4-20mA or 0-10 VDC (Angular X-Y, Parallel X-Y, and Gap at each end), Analog Outputs for Connection to DCS
 
Power Input 90-264VAC, 50/60Hz, or 24VDC